Jiangsu Changsheng Cable Co., Ltd.

home products Special cable for frequency conversion electric eq Special cable for frequency conversion electric equipment

Special cable for frequency conversion electric equipment

Product Details:

Type high temperature resistant
Usage Industrial
Insulation Material XLPE
Jacket Rubber
Place of Origin Jiangsu, China (Mainland)
Brand Name CHANGSHENG
Model Number BPTGPLDQPL

Payment & Shipping Terms:

Minimum Order Quantity: 1000 Meter
Price: FOB Shanghai RMB 1000~1000000
Packaging Details: Packed in wooden disk or mental disk
Delivery Time: 20 days
Payment Terms: L/C,T/T
Supply Ability: 1000000 Kilometer per Year

Detailed Product Description


 

*Features and applications of product

The product is a modified one that is researched and developed by our company recently on the basis of original cable for frequency conversion electric equipment produced by our company and absorbed precious suggestion from customers and referring cable manufacturing standard and normal. Now it has been applied state patent and granted and got patent license. The product adopts the form of compound shield which can withstand strong electrostatic coupling, electromagnetic induction, electric wave, bad grounding and conduction interference of main lead. When circuit arise current component of higher harmonic and side frequency harmonic, the sum of current at shielded layer will be zero. Therefore it cant produce interference to outside. The product is suitable for frequency control transmission device of roll machine and power line and transmission and distribution line where has strict shielded requirement with 0.6/1kv and below. It is widely used for metallurgy industry, power industry, petrochemical industry, etc.

*Executive standard of product

Enterprises standard

Test of flame retardant and fire resistance accord to GB 12666-90 standard.

*Features of application

1. AC rated voltage: U0/U 0.6/1kv

2. Maximum temperature of conductor:

For silicon rubber insulation: 180oC

For fluoroplastic insulation: 200oC

For soluble PTFE: 260oC

For PVC insulation: 70oC

For XLPE insulation: 90oC

3. The minimum ambient temperature:

For fluoroplastic and silicon rubber sheath:

Fixed laid down: -60oC

Non-fixed laid down: -15oC

For PVC insulation:

Fixed laid down: -40oC

Non-fixed laid down: -15oC

4. Installed and laid down temperature of cable: should not be below 0oC (for fluoroplastic, silicon rubber, NBR, not less than -25oC

5. The permitted bending radius of cable:

  The minimum value will be 15 times of its outer diameter.

*Basic type and name

Type

Name   of     product

BPTVPLVPL

Flame retardant PVC insulation and sheath compound shielded frequency conversion cable.

BPTYJPLVPL

XLPE insulation flame retardant PVC sheath compound shielded frequency conversion cable

BPTGPLVPL

Silicon rubber flame retardant PVC sheath compound shielded high temperature resistant frequency conversion cable

BPTGPLGPL

Silicon rubber insulation and sheath compound shielded high temperature resistant frequency conversion cable

BPTGPLDQPL

Silicon rubber insulation NBR sheath compound shielded high temperature resistant frequency conversion cable

BPTGPLDQPL-105

Silicon rubber insulation 105 NBR sheath compound shielded high temperature resistant frequency conversion cable

BPTFPLVPL

Fluoroplastic insulation flame retardant PVC sheath compound shielded high temperature resistant frequency conversion cable

BPTFPLFPL

Fluoroplastic insulation and sheath compound shielded high temperature resistant frequency conversion cable

BPTFPLGPL

Fluoroplastic insulation silicon rubber sheath compound shielded high temperature resistant frequency conversion cable

BPTFPLDQPL

Fluoroplastic insulation NBR sheath compound shielded high temperature resistant frequency conversion cable

BPTFPLDQPL-105

Fluoroplastic insulation 105 NBR sheath compound shielded high temperature resistant frequency conversion cable

*Main technical index

1. DC resistance of finished cable conductor should be in conformity with the regulations of GB3956.

2. Insulation resistance of finished cable at 20oC, for fluoroplastic and silicon rubber: not less than 100MΩ·km, for PVC insulation, not less than 50MΩ·km.

3. The finished cable cannot be broken when withstood 50Hz, 3.5kv for 5 min.

4. Transmission impedance of shielded layer

Transmission impedance of cable at 100MHz should equal to or be less than 100Ω/M.

Ideal shielded inhibit coefficient of cable should equal to or be less than 0.7

Special cable for frequency conversion electric equipment Special cable for frequency conversion electric equipment

Send your message to this supplier
« Prev Product 1 2 Next Product »

Other Products from this Supplier

Company Info

Jiangsu Changsheng Cable Co., Ltd.
[China (Mainland)]
[Verified Member]

City: Changzhou
Province/State: Jiangsu
Country/Region : China (Mainland)

Business Type:Manufacturer

View Contact Details

Email this page Bookmark this page Print this Page